LC-MS/MS, 4000 Q Trap, Sciex (2009)










TurboIonSpray® probe flow rate range

5 to 3000 μL/min

APCI probe flow rate range

200 to 3000 μL/min



Dynamic Range

1 cps to 4 x 106cps (pulse counting)

Scan Type

Q1MS, Q3 MS, Product ion, Precursor ion, Neutral Loss or gain, MRM

Scan speed

User-settable scan speeds of 250 amu/sec, 1000 amu/sec and 4,000 amu/sec in linear ion trap mode. Maximum of 2,400 amu/sec in RF/DC mode

NanoSpray™ source with the MicroIonSpray® head flow rate range

0.05 to 2.0 μL/min

Mass Range

m/z of 5 to 2800 in Q1/Q3 RF/DC mode, m/z of 50 to 2800 in linear ion trap mode

NanoSpray™ source using the continuous NanoSpray™ head flow rate

0.05 to 0.5 μL/min

NanoSpray™ source with discrete NanoSpray™ head flow rate

0.02 to 0.05 μl/min

Mass Stability

At vacuum and electronics equilibrium, 0.1 amu over 9 hrs at m/z 2010 with normal operating temperature

Mass Resolution

>3000 at m/z 609 at 250 amu/sec

Physical Specifications


130 cm (53 in)


50 cm (20 in)


136 kg (299 lb)


52 cm (21.5 in)

Computer Requirements (PC)

Operating System                   

Windows 2000


40x/10x/40x CDRW


1.44 MB


256 MB


2.53 GHz

Hard Disk

40 GB


18 inches Viewable Flat Panel Monitor recommended

Power Requirements

Power Consumption           

2500VA max


2 separate 208V minimum to 242 V maximum

Frequency Hz

50/60 Hz

Circuit Current

15A grounded single-phase circuit



LC-MS/MS enables quantitative and qualitative analysis within a single system. Use of a quadrupole mass spectrometer as a linear ion trap significantly enhances ion trap performance by increasing ion capacity, improving injection and trapping efficiencies, and increasing duty cycle.The high sensitivity of this instrument ensures low detection limits. Efficient ionization and superior ion sampling of the interface result in excellent sensitivity. Easy-to-use Turbo V Source allows to quantitate over a wide range of flow rates and to change rapidly between atmospheric-pressure chemical ionization (APCI) and TurboIonSpray Probes. The optional DuoSpray Ion Source accelerates method development and increases both throughput and data quality. An additional option for APCI, the PhotoSpray Source, expands the range of compounds for analysis. The software applications enable automated MS to MS/MS acquisition, allows to extract the maximum amount of information from a single LC-MS run.The superior ionization efficiency, enhanced robustness, and ease-of-use of the innovative Turbo V Source, combined with the LINAC Collision Cell give high performance and high productivity with greater confidence.




Sample instructions








National Lab/R&D's


Standarization& Estimation

Rs. 6000/-

Rs. 6000/-

Rs. 6000/-

Per component/sample

Subsequent sample per element

Rs. 6000/-

Rs. 6000/-

Rs. 6000/-

Per component/ sample

Sample Preparation

Rs. 2000/-

Rs. 2000/

Rs. 2000/

Per Sample

Terms & Conditions  |  Copyright Policy  |  Privacy Policy  |  Hyperlinking Policy  |  Help

All Rights Reserved © Central Institute of Fisheries Technology (CIFT)

Website Powered by iDynasite from INI Technologies Pvt Ltd, India

Page Last Updated on : 11-01-2018

Visitors Count:

Quick Links